top of page
IMG-20250621-WA0046.jpg

Our Core Services

Electrical Safety Services

Review of as built design, protection scheme, short circuit study, earthing, lightning protection, arc flash study, electrical hazard operability (eHAZOP)

 

Electrical safety audit, gaps identification with report on short and long term recommendations as per latest standards

 

Gaps closing by solutions design and implementation with supply, installation and commissioning

 

Electrical Safety Training covering scope as per international standards and CEA Safety Guidelines 2021 along with certification to core electrical, mixed and management groups

​

Higher workplace safety with compliance by our safety services and products on fast tangible and intangible return on investment of your resources

​

Energy Services

 

Detailed Energy Audit of Electrical, Thermal, Process, Mechanical including Power quality and Thermography with short and long term recommendations report

 

Gaps closing with Solution design for higher efficiencies, supply installation and commissioning of process instrumentation for flow, level, pressure, temperature measurement, power quality analyzers, harmonic filters, reactive power compensation, vfd, motor protection and control along with online and offline dcs, ems for single window dashboard view of process and electrical parameters

​

​10% direct and 10% indirect savings on energy along with improved power quality and system stability by our energy services and products also helping in improvement of your environment compliance index

​

IMG-20250621-WA0042.jpg
IMG-20250519-WA0005.jpg

Arc Flash Study

The arc flash hazard analysis takes into account where in the system the fault occurs and how long the current exists before a protective device clears the fault. Therefore the protective device coordination needs to be investigated.

The amount of energy liberated during a fault can then be determined. All of these factors result in a specific calories-per-square-centimeter (cal/cm2) value of incident energy that is calculated for each point in the system.

This value indicates the level of personal protective equipment (PPE) that a worker must wear to safely perform any exposed energized work on the equipment.

IMG-20250621-WA0019.jpg

Electrical Safety Audit

This Electrical Safety Audit is comprised of a review of any existing Electrical Safety Program documentation (or other supporting documents), onsite interviews (Electrician’s interview typically takes 1.5 hours and Manager/Supervisor interview takes 1 hour), and observations (both facility inspections and work task (if the opportunity is available).

The context of the Electrical Safety Audit will be to assess the status of existing use of Electrical Specific PPE, Electrical Safe Work Procedures and Electrical Safety & Technical Training as it pertains to managing electrical hazards and minimizing exposure to workers when they must complete exposed energized electrical work.

Consistency with NFPA 70E, Standard for Electrical Safety in the Workplace and industry accepted best practices will be measured.

The review and audit services provided will include the provision of an Audit Team, combined with support from appropriate Company staff in a supporting role.

IMG-20250621-WA0033.jpg

Energy Audit

Most companies now realize that it is not sufficient to implement a generic, “one size fits all” energy plan. For an effective response, with respect to maintaining the energy management system, such a plan must be customized to fit to a company.

 

A more difficult task is the compilation of an implementation plan that balances the requirements of the standard, the business needs and the certification deadline  

 

"The goal for any organization should be to reduce energy consumption and spend through methods of improved energy efficiency and energy management. Through the process of thorough Investigative Data Analysis, companies are quickly able to identify where cost savings can be made and energy saved. Sometimes the outcome of IDA is astonishing, revealing energy saving opportunities not previously prominent on the radar”

 

“Using energy efficiently helps organizations save money as well as helping to conserve resources and tackle climate change”

IMG-20250812-WA0078.jpg

Lightning Protection System Audit Study Design

Very high system currents are developed in the system due to resistance drop in the event of a short circuit fault and cloud discharge in the event of a lightning strike respectively.

It can cause irreversible damages to an installation, facility or life.

 

Appropriate interconnected Earthing System in coordination with lightning design must be in place to allow clearing path for these fault or unwanted currents.

 

It is seen that in the design of new installations these two aspects are considered but with the aging and loading effects the designs of past either don’t hold to the rated requirements and latest regulations,

 

Or unwarranted maintenance of lightning rods, earth pits, down conductors, earthing rods etc. as well as change in soil properties over time leads to an unsure and unsafe situation to Utility Services Manager, Operation Heads and workers. However it’s recommended that checking on Earthing and Lightning design at facilities should be the regular activity in the standard operating procedures for a better workplace safety and efficient operations.

IMG-20250527-WA0043.jpg

Relay Setting Calculation and Coordination

Short Circuit Study and  Relay Coordination as per IEEE 399, 242/3000

IMG-20250830-WA0016.jpg

Earthing Audit with Continuity check and soil resistivity testing

Earth Resistance Value testing at pits and continuity with bonding check on systems by loop impedance and through the earth loops method to crosscheck fault clearance paths as well as step touch and gpr per IEEE80, IS3043,  IEC60364 along with earth grid modelling validation and redesign on CDEGS as per fault clearance time current curves

WhatsApp Image 2026-01-09 at 11.00.43 AM.jpeg

Transformer Testing

Insulation Resistance, Polarization Index, Voltage Ratio, Vector Group. Turn Ratio, Magnetizing Current, Protection Check, OTI WTI  BH check along with control wiring

IMG-20250527-WA0035.jpg

Power Quality Analysis

Power Quality Analysis for harmonics level, unbalance, power factor, zero sequence, phasor, frequency, short and long term flicker checks for backfeed heating effect on motors drives transformers and lines

7.jpg

Safety Trainings

Safety Trainings custom to the process and facility, online and inhouse with demonstrations, to enable key workforce on ground absorb learn important aspects of safety while working around charged systems towards non negotiable workplace safety and zero incidents policy implementation

IMG-20250621-WA0056.jpg

Get a Quote

Let us begin the journey of safety, energy utilization and reliability index improvement with our expert services implementation to your works, processes and facilities

Thanks for submitting!

©2026 AI Electricals 

​